New Products

Voice Alarm System PC1004U

FEATURES:
The system meets the IEC 60849 standards.
The built-in hand-held emergency microphone with the highest priority, and with an emergency trigger switch; the self-test function can detect if the microphone is damaged.
The built-in alarm sound generator can store 110 pieces of sound information; the programmable warnings trigger the corresponding number of regional and sound information; a trigger point can repeat any piece of five sound messages; the sound messages can be recorded through the MIC or LINE input, or through the SD card with self-test function for file errors.
The fire sound system with remote monitoring function, automatically recording the system operations and fault events, can print out the daily records.
A remote paging microphone can be added up to the device, which can be extended to 100 remote paging microphones.
With the incident response buttons and reset button, the two sound messages can be triggered manually, which can accept the PC1019 programmed sound messages by fire matrix triggers.
MCU has the watchdog and self-test functions, using the 640 x 480 industrial-grade color screen and lights to display status, with the machine self-test function when power-on, with the output level indicator for sound messages.
It makes a fire and background music broadcasting system with an existing PC10 system; the background music can be achieved timing or manual functions to switch the sound resources. See pictures for more details.
The system equipments can be tested from sound messages or emergency microphones to speakers, with online real-time detection.
With main and spare power supply functions at the same time, the boot time is <10S to normal operation when the power is on, and <3S from alarm trigger to alarm.
Main and spare power amplifier real-time detection can achieve the functions of 4 main amplifiers to one spare, to simplify the number of standby amplifiers.
The speaker on-line real-time detection.
The system supports the functions of speaker line lightning protection.
The system can support the telephone broadcasting function.
With override function for emergency zone controllers.vThe 100 zones can be supported, enabling neighborhood emergency broadcast functions.

Basic Devices of the Sound Systems for Emergency Purposes (EN 60849)
Voice Alarm System PC1004U
CD Player PC1007C
Pre-Amplifier PC1011P
Indirect Speaker Selector PC1013B
Alarm Matrix PC1019A
M/S Amplifiers Auto Switcher PC1021M
Lightning Conductor PC1024L
Impedance Detector PC1026I
Power Amplifier PC1700
Power Amplifier PC1700
Power Amplifier PC1700
(Emergency Power System PC1022E)
(Battery PC1022B)


SPECIFICATIONS:
Public Address System
    1. Company Profile
    2. Company ProfileDSPPA Audio Co., Ltd. (DSPPA), founded in 1988, is a global famous manufacturer of professional audio products. DSPPA is a specialist for developing and producing the public address (PA) devices and is famous for its hig......
    1. Company History
    2. Company History 1988 : Established as Shenbao A / V Equipment Company. 1990 : Developed the first Stereo Decoder SG9200 in China, which was awarded "The Prize of National Science        &......
    1. Sales Worldwide
    2. Sales Worldwide ......
    1. Quality Assurance
    2. Quality AssuranceDSPPA has obtained many types of certificates for quality warranty, such as ISO9001 authentication, China Compulsory Certification (CCC) certificate, CE certificate, and CB certificate etc. Our company has advanced produ......
    1. Main Production Equipments
    2. Main Production Equipments Main Production Equipments SMT Dispenser Automatic Reflow Machine Wave Soldering Machine Loose Radial Lead Cutter Automatic Components Molding Machine Name of Equipments Quantity ......
    1. Quality Control
    2. Quality Control Main Inspection Equipments ROHS Tester Constant Temperature and Humidity Chamber Salt Spray Tester Accelerated Weathering Test Chamber EMC Test Chamber Vibration Test Machine Anechoi......
    1. Factory Background Broadcast and Fire Protection Broadcast System Design Plan
    2. Factory Background Broadcast and Fire Protection Broadcast System Design Plan Factory Background Broadcast and Fire Protection Broadcast System Design PlanProject overview The area of the factory is about 26000 which is divided into six parts: The fist workshop building; The se......
    1. Background Broadcast Project of Guangzhou ZOO
    2. Background Broadcast Project of Guangzhou ZOO Background Broadcast Project of Guangzhou ZOOProject overviewThe area of the park is about 30,000 which is divided into four zones: 1. Small animal zone, including the entrance plaza;2. Beast zone.User Requirements 1. M......
    1. Hotel Public Address System Design Project
    2. Hotel Public Address System Design Project Hotel Public Address System Design ProjectProject overviewGuangzhou XX Hotel is a 27-floor building, with the underground machine room and parking garage. We set the system into 27 zones, each floor as one zone.User req......
    1. Design Project for Bell Ring, Background Broadcast and Gym Music Broadcast in School
    2. Design Project for Bell Ring, Background Broadcast and Gym Music Broadcast in School Design Project for Bell Ring, Background Broadcast and Gym Music Broadcast in SchoolProject OverviewThe total area of the campus is 12000M2 , including the following parts:1, 2, 3: Class rooms of junior grade one, junio......